Nickel hypersensitivity and skin patch testing in total hip replacement surgery: a systematic review

in EFORT Open Reviews
Authors:
Anna Bogdanova-Bennett Academic Surgical Unit, South West London Elective Orthopaedic Centre, Epsom, UK

Search for other papers by Anna Bogdanova-Bennett in
Current site
Google Scholar
PubMed
Close
,
Amit Sagi Academic Surgical Unit, South West London Elective Orthopaedic Centre, Epsom, UK

Search for other papers by Amit Sagi in
Current site
Google Scholar
PubMed
Close
,
Vipin Asopa Academic Surgical Unit, South West London Elective Orthopaedic Centre, Epsom, UK

Search for other papers by Vipin Asopa in
Current site
Google Scholar
PubMed
Close
,
Richard E. Field Academic Surgical Unit, South West London Elective Orthopaedic Centre, Epsom, UK

Search for other papers by Richard E. Field in
Current site
Google Scholar
PubMed
Close
, and
David H. Sochart Academic Surgical Unit, South West London Elective Orthopaedic Centre, Epsom, UK

Search for other papers by David H. Sochart in
Current site
Google Scholar
PubMed
Close

Anna Bogdanova-Bennett, Mole Valley Building, Epsom General Hospital, Dorking Road, Epsom KT18 7EG, UK. Email: a.bogdanova@nhs.net
Open access

  • Approximately 60,000 cemented femoral stems are implanted in the UK each year with the majority being manufactured from stainless steel containing 10–15% nickel. Nickel hypersensitivity has been reported in up to 13% of the general population and there is a concern that nickel hypersensitivity might adversely affect the outcome of total hip replacement (THR). We reviewed the current literature on the potential link between nickel hypersensitivity and THR complications, and the usefulness of patch testing.

  • We conducted a literature search in PubMed, MEDLINE and EMBASE databases. The level of evidence and the quality of the selected studies were assessed using the Oxford Centre for Evidence-Based Medicine Criteria and the Methodological Index for Non-Randomised Studies tool, respectively.

  • Twenty-six studies met the inclusion criteria, reporting on 1852 patients who underwent primary or revision THR. All studies detailed skin patch testing and recorded prevalence of nickel hypersensitivity from 1.5% to 33.3%. Five studies reported a rise in Nickel hypersensitivity following THR, while four reported a decreased prevalence post-operatively. Eight studies concluded that metal hypersensitivity could have developed following THR, while seven studies did not support a link between metal hypersensitivity and THR complications. Four of the studies recommended routine patch testing pre-operatively, but three others concluded that routine patch testing was not indicated.

  • We have not identified a link between nickel hypersensitivity and THR complications, and the role of patch testing remains unclear. Further large-scale studies would be required to investigate this relationship and to clarify the role of patch testing in facilitating implant selection.

Cite this article: EFORT Open Rev 2021;6:825-838. DOI: 10.1302/2058-5241.6.210051

Abstract

  • Approximately 60,000 cemented femoral stems are implanted in the UK each year with the majority being manufactured from stainless steel containing 10–15% nickel. Nickel hypersensitivity has been reported in up to 13% of the general population and there is a concern that nickel hypersensitivity might adversely affect the outcome of total hip replacement (THR). We reviewed the current literature on the potential link between nickel hypersensitivity and THR complications, and the usefulness of patch testing.

  • We conducted a literature search in PubMed, MEDLINE and EMBASE databases. The level of evidence and the quality of the selected studies were assessed using the Oxford Centre for Evidence-Based Medicine Criteria and the Methodological Index for Non-Randomised Studies tool, respectively.

  • Twenty-six studies met the inclusion criteria, reporting on 1852 patients who underwent primary or revision THR. All studies detailed skin patch testing and recorded prevalence of nickel hypersensitivity from 1.5% to 33.3%. Five studies reported a rise in Nickel hypersensitivity following THR, while four reported a decreased prevalence post-operatively. Eight studies concluded that metal hypersensitivity could have developed following THR, while seven studies did not support a link between metal hypersensitivity and THR complications. Four of the studies recommended routine patch testing pre-operatively, but three others concluded that routine patch testing was not indicated.

  • We have not identified a link between nickel hypersensitivity and THR complications, and the role of patch testing remains unclear. Further large-scale studies would be required to investigate this relationship and to clarify the role of patch testing in facilitating implant selection.

Cite this article: EFORT Open Rev 2021;6:825-838. DOI: 10.1302/2058-5241.6.210051

Introduction

Total hip replacement (THR) is a frequently performed surgical procedure and in England, Wales and Northern Ireland with more than 90,000 hip replacements performed in 2019.1 Metallic implants used in orthopaedic surgery are made of stainless steel, cobalt-chromium-molybdenum, titanium, zirconium and aluminium alloys, which contain a variety of metallic elements including chromium, nickel, manganese, molybdenum, cobalt, iron, titanium vanadium and zirconium.2 The potential effects of pre-existing or developing hypersensitivity to these metals have been raised as a concern in orthopaedic surgery over the last half-century.3

Metal hypersensitivity is a type IV (or delayed-type) hypersensitivity reaction, which occurs when the body develops an immunological reaction to the metallic constituents of an implant. It has been estimated that cutaneous allergies to common metals such as nickel, cobalt and chromium occur in 13%, 2% and 1% of the general population respectively.4 Since these metals are commonly used in THR implants, it has been suggested that patients who are hypersensitive to them may develop a hypersensitivity reaction post-operatively.5 Metal hypersensitivity reactions in orthopaedic patients have been reported to present with localized pain, swelling, redness, warmth, itching and burning, as well as implant loosening that may mimic suspected infection.6 Metal hypersensitivity is considered to be a diagnosis of exclusion when the other causes of implant failure have been ruled out.5 Despite the lack of an established standard for diagnosing metal hypersensitivity, investigations such as skin patch and lymphocyte transformation testing have been advocated.5

Nickel is the fifth most common element on Earth and is widely used in everyday items including jewellery, clothing fasteners, kitchenware and coins, as well as in the steel and military-related industries. Nickel is a moderate sensitizer and in 1925 was demonstrated to be the aetiological factor in the development of dermatitis in workers from the electroplating industry.2 Subsequent studies investigated the role of nickel hypersensitivity in a variety of occupations, with a Swedish study demonstrating an increased prevalence in cleaners.7 A high prevalence of nickel dermatitis was found in cooks with the increased use of stainless steel kitchenware8 and in Britain in the late 20th century it was reported that hairdressers, cleaners and cooks with diagnosed occupational contact dermatitis usually had an established nickel hypersensitivity.8 In Finland, nickel was implicated in 6.9% of occupational contact dermatitis cases, involving occupations such as machine and metal product assemblers, electrical equipment assemblers, footwear workers, industrial tailors, hairdressers and beauticians.9

The proportion of nickel in stainless steel is considerably higher than in cobalt-chrome (13–15%10 against 1%11). In the UK, the femoral component of approximately two-thirds of all hip replacements is secured with bone cement. Almost all of these 60,000 stems are manufactured from stainless steel.1 Over time, all metallic alloys corrode, particularly at junctions and when in contact with biological fluids. Therefore, it may be hypothesized that patients who are already sensitive to nickel could be more likely to experience a peri-articular reaction compared to those with no history of metal sensitivities. If this hypothesis was confirmed, patch testing, prior to orthopaedic device implantation, would be a useful tool to identify patients with nickel hypersensitivity.12 It would then allow appropriate consideration for using a low or non-nickel containing implant.

We have reviewed the current literature and collated the evidence concerning the relationship between nickel hypersensitivity in patients with total hip replacement and any associated complications, along with the usefulness of patch testing in identifying nickel hypersensitivity. We have assessed the potential link between nickel hypersensitivity and THR complications as well as the usefulness of patch testing.

Methods

Search strategy and study selection

Systematic electronic literature searches were conducted in PubMed, Ovid and Healthcare Database Advanced Search (HDAS) searching EMBASE and Medline databases (until 13 April 2021). Combinations of medical subject heading (MeSH) terms and keywords were used to identify relevant papers with a high level of sensitivity. Table 1 shows the search string applied in the search. Further manual searches of the reference lists of the papers and searching the grey literature supplemented the systematic electronic search. Papers were screened initially by title and abstract. Two independent reviewers screened the selected studies and the results of the search strategy were reported in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) tool.

Table 1.

Search strategy

Keywords
1 exp total hip replacement/or exp hip replacement/
2 hip prosthesis/
3 (THR or "total hip replacement" or THA or "total hip arthroplast*" or "hip surger*" or "hip prosthes*" or "total hip prosthes*").mp. [mp=title, abstract, heading word, drug trade name, original title, device manufacturer, drug manufacturer, device trade name, keyword, floating subheading word, candidate term word]
4 hip surgery/
5 1 or 2 or 3 or 4
6 Nickel hypersensitivity/
7 ("Nickel allerg*" or Nickel or "Nickel hypersensitiv*" or "Nickel reaction*").mp. [mp=title, abstract, heading word, drug trade name, original title, device manufacturer, drug manufacturer, device trade name, keyword, floating subheading word, candidate term word]
8 6 or 7
9 5 and 8

Eligibility criteria

The inclusion criteria were: (1) clinical studies on testing nickel hypersensitivity with patch testing in patients with THR; (2) published in English or with translation freely available; (3) full text of studies available. Exclusion criteria included (1) case reports; (2) review studies; (3) cadaver studies and (4) no reported outcome.

Data extraction/analysis

The level of evidence (LE) was assessed based on previously published criteria from the Oxford Centre for Evidence-Based Medicine13 and the methodological quality was assessed using the Methodological Index for Non-Randomised Studies (MINORS) tool.14 The following information was obtained from each study:

  1. Study characteristics (e.g. author, geographical area, study design)

  2. Patient characteristics (e.g. number of patients included, and number of hip joints operated on, age, gender)

  3. Implant characteristics (e.g. type of implant, bearing)

  4. Details on patch testing (patch substances used; time point at which patch test was performed)

  5. Prevalence of nickel hypersensitivity (before and/or after surgery)

  6. Clinical results (e.g. complications, stable or failed implant, adverse reaction to metal debris, systemic adverse reactions)

  7. Main conclusions and recommendations

Results

Search results

Our initial literature search using the MeSH terms detailed in Table 1 identified 795 studies, and after the duplicates were removed 439 remained. The abstracts of these papers were screened. Twenty-six clinical studies met the inclusion criteria for this review (Fig. 1).

Fig. 1
Fig. 1

Preferred Reporting Items for Systematic Review and Meta-Analyses (PRISMA) study selection flow diagram.

Citation: EFORT Open Reviews 6, 10; 10.1302/2058-5241.6.210051

Quality assessment

All studies were of small to medium size and focused on metal and/or nickel sensitivity in patients who underwent total hip arthroplasty. Seven of the studies18,20,24,2628,39 had a cohort study design with LE of III, while the other 19 were case-series16,21,25,2934,37,40 or case-controlled15,17,19,22,23,35,36,38 with LE of IV. The average MINORS score was 12.2 (Table 2).

Table 2.

Study characteristics with level of evidence (LE) and Methodological Index for Non-Randomised Studies (MINORS) score

Author Year Study design Country Number of patients Age (mean) LE MINORS score
Benson et al15 1975 Case-control UK 105 67 IV 13
Brown et al16 1977 Case-series US 20 62 IV 9
Carlsson et al17 1980 Case-control Sweden 274 64 IV 14
Carlsson and Möller18 1989 Cohort study Sweden 18 NR III 13
Christiansen et al19 2019 Case-control Denmark 20 65 IV 19
Deutman et al20 1977 Cohort study Netherlands 212 NR III 14
Elves et al21 1975 Case-series UK 50 NR IV 9
Frigerio et al22 2011 Case-control Italy 100 68 IV 10
Granchi et al23 2005 Case-control Italy 223 63 IV 13
Guenther et al24 2016 Cohort study Germany 17 58 III 20
Gustafson et al25 2014 Case-series Denmark 54 64 IV 11
Hallab et al26 2013 Cohort study US 58 64 III 18
Hjorth et al27 2015 Cohort study Denmark 41 52 III 14
Kręcisz et al28 2012 Cohort study Poland 60 62 III 13
Lodi et al29 1995 Case-series Italy 64 66 IV 9
Milavec-Puretić et al30 1998 Case-series Croatia 40 60 IV 10
Nater et al31 1976 Case-series Netherlands 66 70 IV 10
Pazzaglia et al32 1983 Case-series Italy 40 69 IV 7
Rooker and Wilkinson33 1980 Case-series UK 67 NR IV 10
Shanmugham et al34 2020 Case-series India 54 NR IV 12
Thomas et al35 2013 Case-control Germany 368 63 IV 13
Thomas et al36 2015 Case-control Germany 250 65 IV 13
Thomas et al37 2009 Case-series Germany 16 68 IV 12
Thyssen et al38 2009 Case-control Denmark 1068 NR IV 19
Waterman and Schrik39 1985 Cohort study Netherlands 85 71 III 10
Zeng et al40 2014 Case-series China 96 48 IV 9

Note. NR, not recorded.

Cohort characteristics

Across all of the studies there were 3466 participants with an average age of 63.5 years (range 48–71) and average female proportion of 65.7% (range 24–89%). A total of 1852 primary and revision hip arthroplasties were performed, either prior to the conducted studies or as part of them. The rest of the participants either comprised control groups or underwent a different procedure, such as total knee replacement (TKR), or open reduction and internal fixation (ORIF). A detailed description of the study populations is shown in Table 3.

Table 3.

Summary of the included studies with breakdown of number of hip replacements, total number of participants in each study, average age, proportion of female participants, the description of each study population, and the type of implant and bearing used

Study Number of hip replacements

(number of participants)
Average age Proportion of females Population Type of implant Bearing
Benson et al 197515 91 joints

(105 participants)
67.0

(range NR)
67% 72 patients with THR 39 patients – Charnley prosthesis

32 patients – McKee

1 patient – Stanmore
40 patients – MOP

32 patients – MOM
33 control group – awaiting THR
Brown et al 197716 23 joints

(20 participants)
62.0

(range 29–80)
80% 20 patients with THR and sterile loosening of implant 20 patients – McKee-Farrar

(2 patients with previous Vitallium Austin Moore and 1 with a previous Vitallium Cup)
20 patients – MOM
Carlsson et al 198017 134 joints

(134 participants)
61.0 (±8) 59% Group I - retrospective sample of 134 patients with THR 89 patients – stainless steel (Charnley)

45 patients – CoCr
89 patients – MOP
112 joints

(112 participants)
65.0 (±9) 65% Group II – prospective sample of 112 patients awaiting THR Stainless steel or

Cobalt-chromium
(28 participants) 66.0 (±12) 57% Group III – prospective sample of 28 patients awaiting operation
Carlsson and Möller 198918 5 joints

(18 participants)
NR NR 5 patients with THR 14 patients – CrNi

3 patients – CrCoNi

1 patient – CoNi
13 patients with other orthopaedic implants
Christiansen et al 201919 6 joints

(6 participants)
60.8

(range NR)
33% Aseptic loosening

patients for revision THR
3 patients – CoCrMo/TiAlV

2 patients – CoCrMo/FeCrNiMn

1 patient – CoCrMo
5 patients – MOP

1 patient – MOM
6 joints

(6 participants)
73.0

(range NR)
33% THR revision for any other reason than aseptic loosening 2 patients – CoCrMo/TiAlVa

1 patient – TiAlVa/Ceramic

3 patients – CoCrMo/FeCrNiMn
5 patients – MOP

1 patient – COP
8 joints

(6 participants)
62.0

(range NR)
38% Control group received primary THR NR NR
Deutman et al 197720 (212 participants) NR 82% 173 patients with no previous operations
17 patients with other metallic implants but no THR
16 patients to be re-operated 15 patients – McKee-Farrar

1 patient – Muller
15 patients – MOM

1 patient – MOP
6 patients with stable THR contralaterally 6 patients – McKee-Farrar 6 patients – MOM
66 joints

(66 participants)
69.5

(range NR)
83% 66 patients from the previous study who did not have pre-operative sensitivity and underwent THR All patients – Stanmore All patients – MOP
Elves et al 197521 61 joints

(50 participants)
NR NR 40 participants previous THR 36 patients – Stanmore

4 patients – special femoral prosthesis
36 patients – MOM
10 participants with various orthopaedic implants investigated for failure 5 patients – McKee-Farrar (MOM)

5 patients – hip, knee, elbow prosthesis
5 patients – MOM
Frigerio et al 201122 48 joints

(100 participants)
68.0

(range 51–84)
73% 48 patients awaiting THR 24 patients – CoCrMo/TiAlVa

14 patients – TiAlVa

10 patients – CoCrMo
22 patients – COP

12 patients – MOM

7 patients – MOP

7 patients – COC
52 patients awaiting TKR 33 patients – CoCrMo/TiAlV

10 patents – CoCrMo

9 patients – TIAlVa
Granchi et al 200523 (66 participants) 59.6

(range 24–82)
74% Patients awaiting THR
53 joints

(53 participants)
65.0

(range 35–81)
73% Patients with stable THR 27 patients – TiAlVa

24 patients – CoCrMo/TiAlVa

2 patients – CoCrMo
47 patients – COC

5 patients – MOP

1 patient – MOM
104 joints

(104 participants)
64.7

(range 32–83)
75% Patients with loosening of THR 31 patients - CoCrMo

25 patients – TiAlVa

22 patients – CoCrMo/TiAlVa

26 patients – unknown
48 patients – COC

39 patients – MOP

2 patients – MOM

15 patients – COP
Guenther et al 201624 (34914 participants) NR NR Historic database patients with primary and revision hip and knee arthroplasty NR NR
3 joints

(17 participants)
58.2 (±9.8) 100% THR revision for likely allergic reaction 1 patient – Allofit (Zimmer) pure titanium NR
Gustafson et al 201425 54 joints

(54 participants)
64.0

(range 56–70)
64% 44 patients with THR followed up NR 25 patients – MOP/COP implants 19 patients – MOM implants
Hallab et al 201326 26 joints

(58 participants)
NR NR for Group 1&2 Group 1 (n = 21) awaiting THR 38 patients – Conserve plus 38 patients – MOM implants
NR Group 2 (n = 17) with THR
63.5

(range 44–74)
Group 3: 50% Group 3 (n = 20) controls with no implant
Hjorth et al 201527 49 joints

(41 participants)
52.0

(range 26–68)
24% Patients with THR All patients: head (CoCrMo) and stem (TiAlVa) MOM implants
Kręcizs et al 201228 (60 participants) 61.7

(range NR)
72% 39 patients awaiting THR
21 patients awaiting TKR
NR number of hip joints

(48 participants)
NR 75% Patients post TJR NR NR
Lodi et al 199529 66 joints

(66 participants)
65.9

(range 37–88)
80% Patients with THR (13 cases with known aseptic mobilization) NR NR
(41 participants) 61.4

(range 32–82)
71% Control group – 41 patients awaiting THR
Milavec-Puretić et al 199830 40 joints

(40 participants)
Males: 58.7 (range 35–75)

Females: 59.6 (range 29–76)
55% 40 patients undergoing revision THR 25 patients – CoCrMo

2 patients – Stainless steel

3 patients – CoNiCrMo

(for 10 patients – 2nd revision of the same joint)
27 patients – MOP

1 patient – MOM
Nater et al 197631 66 joints

(66 participants)
69.5

(range NR)
89% 66 patients awaiting THR and followed up 6 to 12 months after All patients – Stanmore MOP
Pazzaglia et el 198332 20 joints

(20 participants)
68.8

(range 60–82)
NR 20 patients with THR All patients – Charnley implants MOP
Control group – 20 patients without implant
Rooker et al 198033 67 joints

(69 participants)
NR 52% 67 patients awaiting THR 66 patients – Charnley implants

1 patient – Titanium implant
66 patients – MOP
54 patients followed up after
Shanmugham et al 202034 (54 participants) NR NR 54 participants awaiting hip/knee or shoulder replacement
(30 participants) 55.0 (±13.7) 47% 30 participants (out of 54) post hip/knee or shoulder replacement NR NR
Thomas et al 201335 (68 participants) Patients with eczema, but no CMI: 52.4 (range 18–75)

Patients with eczema and CMI: 61.6 (range 44–75)
62% Patients with eczema but without implants
53 joints

(100 participants)
72.4

(range 29–96)
75% 53 patients with symptom-free THR CoCrMo NR
47 patients with symptom-free TKR CoCrMo
13 joints

(200 participants)
64.4

(range 37–84)
65% 13 patients with symptoms/complications of THR CoCrMo NR
187 patients with symptoms/complications of TKR CoCrMo
Thomas et al 201536 61 joints

(250 participants)
64.8

(range 37–84)
66% 61 patients with THR (primary and revision) and suspected of having allergic reactions CoCrMo NR
189 patients with TKR CoCrMo
Thomas et al 200937 16 joints

(16 participants)
Average age NR

(range 52–83)
50% Patients awaiting THR revision due to pain, osteolysis, dislocation, loosening NR MOM implants
Thyssen et al 200938 356 joints

(1068 participants)
NR 67% in THR group 356 patients with previous patch test and THR (primary and revision) NR 83 patients – MOP

25 patients – COP/COC

4 patients – MOM

244 patients – NR
712 control patients from patch database
Waterman and Schrik 198539 95 joints

(85 participants)
71.0

(range 26–90)
88% Patients awaiting THR and followed up post operation 78 patients – Stanmore alluvium

9 patients – Stanmore titanium

2 patients – Monk

3 patients – Freeman double cup

1 patient – Freeman cup-neck

2 patients – Waldemar Link
MOP bearing in all participants
Zeng et al 201440 120 joints

(94 participants)
48.3

(range 22–76)
48% 67 patients awaiting THR and follow up after surgery NR 46 patients – COC

13 patients – COP

5 patients – MOP

3 patients – NR
29 patients awaiting TKR 25 patients – Gemini MKII PS

4 patients – NR

Notes. Al, aluminium; CMI, cutaneous metal intolerance reactions; Co, cobalt; COC, ceramic-on-ceramic; COP, ceramic-on-plastic; Cr, chromium; Fe, iron; Mn, manganese; Mo, molybdenum; MOM, metal-on-metal; MOP, metal-on-plastic; Ni, nickel; NR, not recorded; THR, total hip replacement; Ti, titanium; TJR, total joint replacement; TKR, total knee replacement; Va, vanadium.

Implant characteristics

The implant type and type of bearing was documented in 15 studies,1517,1923,26,27,3033,39 with only the implant type being recorded in four studies18,24,35,36 and only the type of bearing in a further four.25,37,38,40 In the three remaining studies28,29,34 there was no clear documentation of either the type of implant used or the bearing. A breakdown of the type of implants used and the bearing from each study is shown in Table 3.

Patch testing

All 26 studies used patch testing to identify metal hypersensitivity. The substances applied in the patch testing along with the exact concentration of each substance were listed in 20 studies (Table 4). Thirteen of the studies15,17,18,2123,25,2730,34,38 used 5% nickel sulphate, four 20,31,33,39 used 2.5% nickel sulphate, and the remaining three used nickel sulphate in concentrations of 1%,19 2%16 and 3%.32 In the other six studies24,26,3537,40 the strength of the nickel sulphate used was not documented.

Table 4.

Patch test composition for each study

Author Patch test composition
Benson et al15 Nickel sulphate 5%, potassium dichromate 0.5%, cobalt chloride 2%, barium sulphate 10%, benzoyl peroxidase 5%, formaldehyde 2%, hydroquinone 0.2%, monomer methyl methacrylate 1%, polymer 10%
Brown et al16 Nickel sulphate 2%, potassium dichromate 0.5%, cobalt chloride 1%, cobalt sulphate 2%, monomer methyl methacrylate 10%
Carlsson et al17 Nickel sulphate 5%, potassium dichromate 0.5%, cobalt chloride 1%
Carlsson and Möller18 Nickel sulphate 5%, potassium dichromate 0.5%, cobalt chloride 1%
Christiansen et al19 Nickel sulphate 1%, potassium dichromate 0.05%, cobalt chloride 0.02%, methyl methacrylate (2 wt.%), aluminium chloride (0.72, 0.38, 0.039 wt.%), ammonium molybdate (0.12, 0.013, 0.04 wt.%), ammonium titanium lactate, ammonium titanium peroxo-citrate (0.32, 0.16, 0.08, 0.04 wt.%), ferrous chloride (2 wt.%), gentamycin sulphate (20 wt.%), manganese chloride (0.24, 0.08, 0.06, 0.0057 wt.%), potassium titanium oxide oxalate (2.4, 1.2, 0.6 wt.%), solution Ti (0.16, 0.08, 0.04 wt.%), titanium dioxide (0.24 wt.%), titanium oxalate hydrate (0.32, 0.16, 0.08, 0.04 wt.%), vanadium chloride (0.24,0.12, 0.013, 0.04 wt.%), vanadium oxide sulphate hydrate (0.36, 0.18, 0.06, 0.02 wt.%)
Deutman et al20 Nickel sulphate 2.5%, potassium dichromate 0.5%, cobalt chloride 1%
Elves et al21 Nickel sulphate 5%, potassium dichromate 0.5%, cobalt chloride 2%
Frigerio et al22 Nickel sulphate 5%, potassium dichromate 0.5%, cobalt chloride 1%, copper sulphate 2%, molybdenum 5%, palladium 2%, silver nitrate 1%, tin 50%, titanium 10%, vanadium 5%
Grachi et al23 Nickel sulphate 5%, potassium dichromate 0.5%, cobalt chloride 1%, aluminium chloride 1%, chromium trichloride 2%, ferric chloride 2%, manganese chloride 2%, molybdenum chloride 2%, titanium dioxide 2%, vanadium trichloride 2%
Guenther et al24 NR
Gustafson et al25 Nickel sulphate 5%, potassium dichromate 0.5%, cobalt chloride 1%, aluminium chloride 2%, ferric chloride 2%, manganese chloride 2%, molybdenum chloride 2.5%, titanium dioxide 10%, vanadium chloride 1%, zirconium chloride 1%
Hallab et al26 Nickel, cobalt, chromium
Hjorth et al27 Nickel sulphate 5%, potassium dichromate 0.5%, cobalt chloride 1%, aluminium chloride 2%, ferric chloride 2%, manganese chloride 2%, molybdenum chloride 2.5%, titanium dioxide 10%, vanadium chloride 1%, zirconium chloride 1%
Kręcisz et al28 Nickel sulphate 5%, potassium dichromate 0.5%, cobalt chloride 1%, aluminium 100%, ammonium molybdate tetrahydrate 1%, copper sulphate 2%, molybdenum 5%, palladium chloride 2%, vanadium 5%, vanadium chloride 1%, titanium oxide 10%
Lodi et al29 Nickel sulphate 5%, potassium dichromate 0.5%, cobalt chloride 1%, aluminium chloride 1%, chromic chloride 2%, dimethyl phthalate 5%, epoxy resin 1%, ethylene glycol 5%, ferric chloride 2%, methyl methacrylate 5%, molybdenum chloride 2%, molybdenum chloride 5%, manganous chloride 2%, manganous chloride 5%, polyethylene glycol, titanium chloride 1%, titanium dioxide 5%, vanadium trichloride 2%, vanadium trichloride 5%
Milavec-Puretić et al30 Nickel sulphate 5%, potassium dichromate 0.5%, cobalt chloride 1%, acrylate, balsam of Peru 25%, dibutyl phthalate 5%, formaldehyde 1%, metal rust, prostheses scrapings, titanium
Nater et al31 Nickel sulphate 2.5%, potassium dichromate 0.5%, cobalt chloride 1%
Pazzaglia et al32 Nickel sulphate 3%, potassium dichromate 0.5%, ferrous chloride 2%, manganous chloride 2%
Rooker et al33 Nickel sulphate 2.5%, potassium dichromate 0.5%, cobalt chloride 1%, benzoyl peroxide 5%, dimethyl-p-toluidine 2%, hydroquinone 1%, methyl methacrylate 5%
Shanmugham et al34 Nickel sulphate 5%, potassium dichromate 0.5%, cobalt chloride 1%, benzoyl peroxide 1%, gentamicin sulphate 20%, hydroquinone 1%, methyl methacrylate 2%, N, N‑Dimethyl‑4‑toluidine 5%, titanium dioxide 10%, vanadium 5%
Thomas et al35 Nickel, chromium, cobalt
Thomas et al36 29 allergens, routine supplemental series and bone cement component series
Thomas et al37 Nickel, chromium, cobalt, manganous chloride 0.5%, sodium molybdate 2%, titanium dioxide 0.1%
Thyssen et al38 Nickel sulphate 5%, potassium dichromate 0.5%, cobalt chloride 1%
Waterman and Schrik39 Nickel sulphate 2.5%, potassium dichromate 0.5%, cobalt chloride 1%, ammonium molybdate 1%, ammonium vanadate 1%, benzoyl peroxide 1%, hydroquinone 1%, methyl methacrylate 10%, methyl methacrylate 25%, titanium dioxide 5%
Zeng et al40 Nickel, cobalt, chromium, aluminium, copper, iron, manganese, molybdenum, tin, titanium, vanadium, zirconium

Notes. NR, not recorded.

In ten studies17,18,20,22,28,31,33,34,36,39 the participants were patch tested both before and after their operation, and in 14 studies15,16,19,21,2327,29,30,32,35,37 participants were patch tested only after the primary arthroplasty took place. In three studies with patients undergoing revision THR, the timing of patch testing was not documented in relation to the revision procedure.19,30,37 Additionally, in one study six patients had patch testing after the revision; however, for the remaining patients it was not documented when patch testing was performed.16 In the study by Thyssen et al, patch testing was performed prior to THR in 292 cases (82%) and in 64 cases (18%) after THR was performed.38 In one study patch testing was performed prior to primary THR.40

The reported time until patch testing was performed post-operatively ranged from three months to 18 years (Table 5).

Table 5.

Nickel hypersensitivity prevalence across all studies and timing of patch testing. Two studies, highlighted in red, recruited patients with established nickel hypersensitivity as per inclusion criteria

Author Total number of participants Timing of patch testing Prevalence of Nickel sensitivity
Population Number of participants %
Benson et al15 105 patients Post-operatively (after 4.2–5.2 years) Participants with THR (MOM bearing) (n = 33) 3 9.1
Participants with THR (MOP bearing) (n = 39) 1 2.6
Control group (n = 33) 3 9.1
Brown et al16 20 patients NR when performed Participants with THR with sterile loosening (MOM bearing) (n = 20) 0 0.0
Carlsson et al17 134 patients Post-operatively (after 42–71 months) Participants with THR (MOP bearing) (n = 134) 7 5.2
112 patients Pre-operatively (3 months) Before THR 9 8.0
Post-operatively (after 3-12 months) After THR 10* 8.9
28 patients Control group (no implant) 4 14.3
Christiansen et al19 6 patients NR when performed Participants with THR and aseptic loosing 0 0.0
6 patients NR when performed Participants with THR for revision 0 0.0
8 patients Post-operatively Control group (Primary THR) 1 12.5
Deutman et al20 212 patients Pre-operatively Before THR 11 5.2
66 patients Post-operatively (after 6 months) After THR 3* 4.5
Elves et al21 50 patients Post-operatively (between 1–10 years) Participants with THR (n = 45) and any other orthopaedic implant 9 18.0
Frigerio et al22 100 patients Pre-operatively Before operation (either THR or TKR) 21** 21.0
72 patients Post-operatively (after 1 year) After operation NR NR
Granchi et al23 66 patients Pre-operatively Before operation NR 22.7
53 patients Post-operatively (after 1 year) Participants with THR (stable): NR
TiAlV 33.3
CoCrMo/TiAlV 25.9
104 patients Post-operatively (after 1 year) Participants with loosening of THR: NR
CoCrMo 12.9
TiAlV 27.3
CoCrMo/TiAlV 8.0
Unknown 15.4
Gustafson et al25 54 patients Post-operatively (after 5 years) Participants with THR (MOM bearing) (n = 19) 4 21.1
Participants with THR (MOP/COP bearing) (n=25) 7 28.0
Hallab et al26 16 patients Post-operatively (after 4 years) MOM resurfacing implant group 1 6.3
Hjorth et al27 40 patients Post-operatively (after 5–7 years) Patients with THR (MOM bearing) 2 5.0
Kręcisz et al28 60 patients Pre-operatively Before THR (n = 39) and TKR (n = 21) 12** 20.0
48 patients Post-operatively (after 24 months) After hip or knee arthroplasty 10*, ** 20.8
Lodi et al29 66 patients Post-operatively (after 3–18 years) Participants with THR 1 1.5
41 patients Control group 0 0.0
Milavec-Puretić et al30 40 patients Post-operatively (after 7.6 years) Awaiting revision THR 5 12.5
Nater et al31 66 patients Pre-operatively Before THR 0 0
66 patients Post-operatively (after 6–12 months) After THR 3* 4.5
Pazzaglia et al32 16 patients Post-operatively (after 10–13 years) Participants with THR (MOP bearing) 0 0.0
20 patients Control group NR NR
Rooker and Wilkinson33 69 patients Pre-operatively Before THR 3 4.3
Post-operatively (after 3–19 months) After THR (n = 54) 1* 1.9
Shanmugham et al34 54 participants Pre-operatively Before hip/knee or shoulder replacement 3 5.6
30 participants Post-operatively After hip/knee or shoulder replacement 3*,** 10
Thomas et al35 68 patients Without implant 13 19.1
100 patients Post-operatively Participants with THR (stable) 9** 9.0
200 patients Post-operatively Participants with THR (with complications) 35** 17.5
Thomas et al36 48 patients NR From historic database 13** 27.1
250 patients Post-operatively Participants with THR and likely allergic reaction (n = 61) and with TKR and allergic reaction (n = 189) 32*,** 12.8
Thomas et al37 16 patients NR when performed Awaiting revision THR 4 25.0
Thyssen et al38 356 ‘cases’ In 292 cases (82%) pre-operatively

In 64 cases (18%) post-operatively
Participants with THR 36 10.1
712 patients NR Control group 70 9.8
Waterman et al39 85 patients Pre-operatively (67 days on average) Before THR 6 7.1
Post-operatively (after 4-30 months) After THR 8* 9.4
Zeng et al40 96 patients Pre-operatively Before THR (n = 67) NR** 15.5
Carlsson and Möller18 18 patients From previous studies All selected patients were allergic to nickel as per inclusion criteria 18 100
Post-operatively (after 10.4 years on average) 15*,** 83.3
Guenther et al24 34914 patients NR Primary and revision hip and knee arthroplasty from historic database 849 2.4
17 patients Post-operatively (after 2 years on average) Revision hip and knee arthroplasty in patients with known Nickel allergy 13** 76.5

Notes. Al, aluminium; Co, cobalt; COC, ceramic-on-ceramic; COP, ceramic-on-plastic; Cr, chromium; Mo, molybdenum; MOM, metal-on-metal; MOP, metal-on-plastic; NR, not recorded; THR, total hip replacement; Ti, titanium; TKR, total knee replacement; V, vanadium.

*Change in nickel hypersensitivity prevalence when compared to baseline.

**No information about the breakdown number per type of prosthesis.

Prevalence of nickel sensitivity

The prevalence of nickel sensitivity in each study ranged from 1.5% to 33.3%, and two studies16,32 reported no positive reaction to nickel amongst the participants tested. Two studies18,24 had selected only participants with a known hypersensitivity to nickel and subsequently reported nickel hypersensitivity on patch testing of 76.5%24 and 83.3%18 (Table 5, highlighted in pink).

Ten studies17,18,20,22,28,31,33,34,36,39 compared the pre-operative and post-operative prevalence of nickel hypersensitivity in the same groups of patients and in five of these17,28,31,34,39 it was reported there was an increase in the number of patients testing positive for nickel hypersensitivity post-operatively. Kręcisz et al concluded that the increase in nickel hypersensitivity prevalence was minimal (from 20% pre-operatively to 20.8% post-operatively), but it was noted that three patients had developed a new hypersensitivity to nickel following surgery.28

Four studies18,20,33,36 noted a decrease in the number of patients hypersensitive to nickel after the operation. One study22 did not report the results of patch tests post-operatively.

Study recommendations

Eight studies2022,24,28,31,34,39 concluded that orthopaedic implants could trigger metal hypersensitivity in patients, but that the relationship between the hypersensitivity and subsequent implant failure or loosening remained unknown.21,28 Three studies reported a relationship between metal hypersensitivity and prosthesis loosening,15 higher patch test reactivity in arthroplasty patients experiencing complications,35 and a correlation between metal hypersensitivity and post-surgical thigh pain.40

Seven of the studies16,18,19,29,30,33,38 concluded that they did not support a possible relationship between metal hypersensitivity and THR complications, implant loosening or the need for revision. Two of these studies18,33 and one further study32 concluded that the release of metal ions did not result in increased hypersensitivity.

Gustafson et al reported that, despite metal ion concentrations being higher in patients with metal-on-metal bearings, compared to those with metal-on-plastic articulations, there was no difference in the prevalence of metal hypersensitivity between the two groups25 with Hjorth et al reporting no association between the formation of pseudotumours and serum metal-ion levels, metal patch test reactivity or atopic dermatitis in patients with metal-on-metal bearings.27 Two studies investigated lymphocyte-mediated hyperactivity to metals rather than patch test reactions, but the clinical implications of such hyperactivity in patients with THR remained unknown.26,37 One study concluded that it was doubtful that metal hypersensitivity was triggered by THR.17 Granchi et al reported that it had not been possible to establish a cause–effect relationship between sensitization and THR complications but, reported a shorter THR lifespan in patients with a positive result to patch testing.23 One study did not comment on the possibility of sensitization or any potential relationship between metal hypersensitivity and THR complications.36

Twelve studies concluded that patch testing was a valuable tool,16,20,2225,28,31,3436,40 one of which recommended that it should be mandatory,28 with three further studies recommending its targeted use.24,25,34 Five of these studies concluded that patch testing was a valuable diagnostic tool in the detection of metal hypersensitivity,16,35,40 even when the testing was delayed36 and that testing might have an application in identifying sensitization to implants on a larger scale.23 Four studies20,22,28,31 recommended routine patch testing for all patients pre-operatively, one of which suggested that testing should be obligatory.28 Three studies recommended considering the clinical relevance of patch tests25 and only to perform this investigation when there was a known history of hypersensitivity reactions.24,34

Three studies reported that routine patch testing was not required33,39 or that it was unrealistic.17 One study concluded that patch testing was a poor diagnostic tool and might not be sufficient to accurately demonstrate an adaptive immune response.26

Ten of the studies did not comment on the usefulness of patch testing in identifying nickel hypersensitivities (Table 6).15,18,19,21,27,29,30,32,37,38

Table 6.

Study recommendations on the utility of patch testing in metal hypersensitivity in patients with total hip replacement

Studies Conclusion on the role of patch testing in metal hypersensitivity
Brown et al16 Patch testing a valuable diagnostic tool
Granchi et al23
Thomas et al35
Thomas et al36
Zeng et al40
Deutman et al20Frigerio et al22Kręcisz et al28Nater et al31 Recommend routine patch testing

* Kręcisz et al28 concluded patch testing should be mandatory
Guenther et al24Gustafson et al25Shanmugham et al34 Consider clinical relevance and perform patch testing only in patients with a history of allergic reactions
Carlsson et al17 Did not recommend routine patch testing
Rooker et al33
Waterman et al39
Hallab et al26 Poor diagnostic tool
Benson et al15 Did not comment on the utility of patch testing
Carlsson and Möller18
Christiansen et al19
Elves et al21
Hjorth et al27
Lodi et al29
Milavec-Puretić et al30
Pazzaglia et al32
Thomas et al37
Thyssen et al38

Discussion

The topic of nickel hypersensitivity and its implication in total hip arthroplasty remains controversial. We have reviewed the current literature addressing the relationship between nickel hypersensitivity in patients with total hip replacements and post-operative complications, implant loosening and revision and also studies on the value of skin patch testing. Although there have been several previous studies that have examined the relationship between metal hypersensitivity and THR complications, this is the first to also evaluate the application of patch testing in THR patients allergic to nickel and any reported complications which can be attributed to nickel hypersensitivity.

Eight of the studies supported the concept that the use of implants may result in metal hypersensitization.20,21,22,24,28,31,34,39 Five studies17,28,31,34,39 reported increased nickel sensitivity post-operatively and in three of those none of the patients experienced any complications of THR.31,34,39 Kręcizs et al reported that three patients developed a positive reaction to nickel post-operatively and experienced periodical skin lesions, pain, swelling and erythema28 whilst Carlsson et al reported that, in a retrospective cohort, more positive patch tests were observed in patients with THR complications compared to uneventful ones.17

Despite the hypothetical link between THR complications and hypersensitivity, several studies reported that it was difficult to establish whether the hypersensitivity was a cause or a consequence.21,23,33 Several studies recommended further studies on a larger scale to establish the relationship between sensitization and THR,21 between increased metal hypersensitivity and THR failure26 and between post-surgical pain and metal hypersensitivy.40

Seven of the studies did not support a link between nickel hypersensitivity and THR complications16,18,19,29,30,33,38 and Carlsson et al, reporting on patients with known nickel hypersensitivity who were exposed to a nickel implant for an average of six years, reported the development of no orthopaedic complications.18

Patch testing

The systematic review confirmed that there was no consensus on the routine use of patch testing, but the studies were generally consistent in the chemical constituents that were used for the patch testing, although there was a wide range in the timing of administration. Some studies suggested that patch testing was a reliable, gold standard tool in establishing nickel hypersensitivity16,23,35,36,40 and that it should even be mandatory,28 but a similar number recommended that patch testing was not routinely required.17,33,39

A study by Thomas et al evaluated the usefulness of late reading of the patch testing. It reported an overall positive reaction to nickel in 32 patients (12.8%). Eleven of those positive reactions (34.4%) were recorded following a late reading of the patch test at day 6.36 Reed et al, evaluating the usefulness of patch testing in the guidance of implant choice, concluded that patch testing might be helpful prior to operation, but had limited value post-operatively.41 Furthermore, Hallab et al reported that patch testing was a poor diagnostic tool and suggested that there was no correlation with ion levels or measures of hypersensitivity and that there was no correlation with potential adaptive immune response in the deep tissue.26

There is evidence that patch tests have high sensitivity and specificity to detect hypersensitivity, but the immunologic response which occurs is triggered by the intradermal Langerhans cells, whereas the metal hypersensitivity reaction in the joint space is mediated by different mechanisms involving macrophages and lymphocytes.5 Christiansen et al reported that there was a positive correlation between failure of joint arthroplasty and metal hypersensitivity, investigated by in vitro assay on peripheral blood lymphocytes, and that the findings were suggestive that prosthesis failure could be attributed to a cell-mediated immunity to metals.42

It is not therefore clear whether patch testing can accurately predict outcomes and complications following THR.5 Lhotka et al reported a possible relationship between nickel hypersensitivity and reactions to metallic skin clips used for wound closure, but none of the studies included in this review specifically commented on this issue.43

Nickel hypersensitivity prevalence

It has been reported that the prevalence of nickel sensitivity in the general population is approximately 13%,4 but the prevalence of nickel hypersensitivity following patch testing in the studies reviewed was reported to range from 1.5% to 33.3%. This discrepancy can be explained by the number of participants in each study, the inclusion and exclusion criteria, as well as the lack of uniform reporting of the nickel hypersensitivity. Eight of the studies supported the concept that THR triggers metal hypersensitivity in patients,20,21,22,24,28,31,34,39 but in four there was a decrease in nickel hypersensitivity prevalence post-surgery.18,20,33,36 Possible explanations could be false positive results pre-operatively, or false negative results following surgery, or development of immunological tolerance.33

Nineteen of the studies included patients who underwent primary THR.15,17,18,2023,2529,3135,39,40 The nickel hypersensitivity prevalence ranged from 0.0–33.3% across 18 of those studies, while in one study the prevalence was 83.3% as per inclusion criteria.18 Five studies looked at patients awaiting revision THR.16,19,24,30,37 Four of those studies reported nickel hypersensitivity prevalence of 0.0% to 25.0%, whereas in one study patients undergoing revision THR had known nickel hypersensitivity and the prevalence was 76.5%.24 The study by Thyssen et al looked at both primary and revision cases and reported nickel reaction in 11% of the patients with primary THR, 10% in patients undergoing one revision, and 0% in patients undergoing two or three revisions.38 One study investigated metal hypersensitivity in patients with both primary and revision THR; however, it did not comment on the prevalence of each group separately.36 Given the wide range of participants included in each study and the reported nickel hypersensitivity prevalence, it is impossible to compare the sensitivity rates between the two groups.

Implant type and bearing

A variety of implants and types of bearing were featured in the studies reviewed, but only 15 of the 26 studies1517,1923,26,27,3033,39 clearly reported the details of the implant used as well as the bearing or a breakdown of number of patients. Three of the studies28,29,34 reported neither and this made it impossible to compare the nickel hypersensitivity prevalence between patient groups with different implant types or bearings.

Davies et al investigated peri-prosthetic tissue samples from metal-on-metal (MOM) and metal-on-plastic (MOP) THR and compared them to control samples from patients undergoing primary hip replacement. They observed a distinct and different pattern and type of inflammation between the samples, reporting that MOM tissue samples had a more prominent ulcerated appearance with extensive lymphocytic infiltration, while MOP tissue samples were less ulcerated with no plasma cell or lymphocytic infiltration.44 A study by Brien et al reported that loosening of titanium-alloy implants led to disproportionally high levels of titanium and vanadium in synovial fluid and surrounding tissues when compared to cobalt, chromium and nickel levels released from loosened cobalt-chromium or stainless steel implants.45 Although they raised concerns about the metallosis that could occur, it was unclear what effect this had on the eventual outcome of the THR.45

Limitations

There are several limitations in this systematic review, which include the low level of evidence of the studies, the limited number of patients involved in some of them, the methodological variability of the studies and the inadequate reporting of the results of certain studies. While the participant groups appeared similar across all of the studies, it was not possible to directly compare the prevalence of nickel hypersensitivity due to the lack of uniform reporting of the number of participants with positive patch tests in the THR and the control groups.

Several of the articles compared groups of patients undergoing not only hip but also knee22,28,36,40 and shoulder34 arthroplasties. However, the results of the patch testing of those patients were not stratified by the operation undergone, but only as a cohort.18,22,24,28,3436,40 Eleven of the studies were published in the last 10 years19,22,2428,3436,40 but the review also included studies dating back to 1975, with 12 of the papers being published in 1997 or earlier.1518,20,21,2933,39 Despite these limitations, it was still possible to draw some conclusions.

Conclusion

Nickel hypersensitivity is a common phenomenon in the general population. However, it remains unclear whether nickel hypersensitivity causes complications such as persistent pain, loosening of implants or increases the need for revision after THR. It is also unclear whether nickel hypersensitivity is a cause or an effect. The role of patch testing in establishing nickel hypersensitivity remains controversial, and the selection of an implant for patients with established nickel hypersensitivity should be made after discussion with the patient and at the surgeon’s discretion. Further large-scale, appropriately designed studies would be required to establish the relationship between nickel hypersensitivity and THR complications as well as to guide the selection of the most appropriate implant for such patients.

Open access

This article is distributed under the terms of the Creative Commons Attribution-Non Commercial 4.0 International (CC BY-NC 4.0) licence (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed.

The authors would like to thank Ms Irrum Afzal, Research Manager at the Academic Surgical Unit of the South West London Elective Orthopaedic Centre (SWLEOC) and Ms Potenza Atiogbe, Multiprofessional Education and Library Services Manager at Epsom and St Helier’s NHS Trust for their guidance and contribution to the research process behind this systematic review.

ICMJE Conflict of interest statement

All authors declare no conflicts of interest relevant to this work.

Funding statement

No benefits in any form have been received or will be received from a commercial party related directly or indirectly to the subject of this article.

OA licence text

This article is distributed under the terms of the Creative Commons Attribution-Non Commercial 4.0 International (CC BY-NC 4.0) licence (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed.

References

  • 1.

    National Joint Registry (2020). 17th annual report 2020. https://reports.njrcentre.org.uk/Portals/0/PDFdownloads/NJR%2017th%20Annual%20Report%202020.pdf (date last accessed 3 March 2021).

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 2.

    Thyssen JP. Nickel and cobalt allergy before and after nickel regulation: evaluation of a public health intervention. Contact Dermat 2011;65:168.

  • 3.

    Amini M, Mayes WH, Tzeng A, Tzeng TH, Saleh KJ, Mihalko WM. Evaluation and management of metal hypersensitivity in total joint arthroplasty: a systematic review. J Long Term Eff Med Implants 2014;24:2536.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 4.

    Schäfer T, Böhler E & Ruhdorfer Set al. Epidemiology of contact allergy in adults. Allergy 2001;56:11921196.

  • 5.

    Akil S, Newman JM, Shah NV, Ahmed N, Deshmukh AJ, Maheshwari AV. Metal hypersensitivity in total hip and knee arthroplasty: current concepts. J Clin Orthop Trauma 2018;9:36.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 6.

    Baumann CA, Crist BD. Nickel allergy to orthopaedic implants: a review and case series. J Clin Orthop Trauma 2020;11:S596S603.

  • 7.

    Fregert S. Occupational dermatitis in a 10-year material. Contact Dermat 1975;1:96107.

  • 8.

    Shum KW, Meyer JD, Chen Y, Cherry N, Gawkrodger DJ. Occupational contact dermatitis to nickel: experience of the British dermatologists (EPIDERM) and occupational physicians (OPRA) surveillance schemes. Occup Environ Med 2003;60:954957.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 9.

    Kanerva L, Jolanki R, Estlander T, Alanko K, Savela A. Incidence rates of occupational allergic contact dermatitis caused by metals. Am J Contact Dermat 2000;11:155160.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 10.

    Yang K, Ren Y. Nickel-free austenitic stainless steels for medical applications. Sci Technol Adv Mater 2010;11:014105.

  • 11.

    Gao X, He RX, Yan SG, Wu LD. Dermatitis associated with chromium following total knee arthroplasty. J Arthroplasty 2011;26:665.e13665.e16.

  • 12.

    Delimar D, Bohaček I, Paštar Z, Lipozenčić J. Orthopedic and cutaneous reactions to nickel after total hip replacement. Acta Dermatovenerol Croat 2018;26:3943.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 13.

    OCEBM Levels of Evidence Working Group. The Oxford 2011 Levels of Evidence. Oxford Centre for Evidence-Based Medicine. http://www.cebm.net/index.aspx?o=5653 (date last accessed 3 March 2021).

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 14.

    Slim K, Nini E, Forestier D, Kwiatkowski F, Panis Y, Chipponi J. Methodological Index for Non-Randomized Studies (MINORS): development and validation of a new instrument. ANZ J Surg 2003;73:712716.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 15.

    Benson MK, Goodwin PG, Brostoff J. Metal sensitivity in patients with joint replacement arthroplasties. BMJ 1975;4:374375.

  • 16.

    Brown GC, Lockshin MD, Salvati EA, Bullough PG. Sensitivity to metal as a possible cause of sterile loosening after cobalt-chromium total hip-replacement arthroplasty. J Bone Joint Surg [Am] 1977;59-A:164168.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 17.

    Carlsson AS, Magnusson B, Möller H. Metal sensitivity in patients with metal-to-plastic total hip arthroplasties. Acta Orthop Scand 1980;51:5762.

  • 18.

    Carlsson A, Möller H. Implantation of orthopaedic devices in patients with metal allergy. Acta Derm Venereol 1989;69:6266.

  • 19.

    Christiansen RJ, Münch HJ & Bonefeld CMet al. Cytokine profile in patients with aseptic loosening of total hip replacements and its relation to metal release and metal allergy. J Clin Med 2019;8:1259.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 20.

    Deutman R, Mulder TJ, Brian R, Nater JP, Groningen M. Metal sensitivity before and after total hip arthroplasty. J Bone Joint Surg [Am] 1977;59-A:862865.

  • 21.

    Elves MW, Wilson JN, Scales JT, Kemp HB. Incidence of metal sensitivity in patients with total joint replacements. BMJ 1975;4:376378.

  • 22.

    Frigerio E, Pigatto PD, Guzzi G, Altomare G. Metal sensitivity in patients with orthopaedic implants: a prospective study. Contact Dermat 2011;64:273279.

  • 23.

    Granchi D, Cenni E, Trisolino G, Giunti A, Baldini N. Sensitivity to implant materials in patients undergoing total hip replacement. J Biomed Mater Res B Appl Biomater 2005;77:257264.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 24.

    Guenther D, Thomas P, Kendoff D, Omar M, Gehrke T, Haasper C. Allergic reactions in arthroplasty: myth or serious problem? Int Orthop 2016;40:239244.

  • 25.

    Gustafson K, Jakobsen SS & Lorenzen NDet al. Metal release and metal allergy after total hip replacement with resurfacing versus conventional hybrid prosthesis. Acta Orthop 2014;85:348354.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 26.

    Hallab NJ, Caicedo M, McAllister K, Skipor A, Amstutz H, Jacobs JJ. Asymptomatic prospective and retrospective cohorts with metal-on-metal hip arthroplasty indicate acquired lymphocyte reactivity varies with metal ion levels on a group basis. J Orthop Res 2013;31:173182.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 27.

    Hjorth MH, Stilling M & Søballe Ket al. No association between pseudotumors, high serum metal-ion levels and metal hypersensitivity in large-head metal-on-metal total hip arthroplasty at 5–7-year follow-up. Skeletal Radiol 2015;45:115125.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 28.

    Kręcisz B, Kieć-Świerczyńska M, Chomiczewska-Skóra D. Allergy to orthopedic metal implants: a prospective study. Int J Occup Med Environ Health 2012;25:463469.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 29.

    Lodi A, Chiarelli G, Mancini LL, Cancilleri F, Parrini L, Crosti C. Skin sensitivity to endoprosthetic materials in the recipients of hip prostheses. Contact Dermat 1995;32:5859.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 30.

    Milavec-Puretić V, Orlić D, Marusić A. Sensitivity to metals in 40 patients with failed hip endoprosthesis. Arch Orthop Trauma Surg 1998;117:383386.

  • 31.

    Nater JP, Brain RG, Deutman R, Mulder TJ. The development of metal hypersensitivity in patients with metal-to-plastic hip arthroplasties. Contact Dermat 1976;2:259261.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 32.

    Pazzaglia UE, Minoia C, Ceciliani L, Riccardi C. Metal determination in organic fluids of patients with stainless steel hip arthroplasty. Acta Orthop Scand 1983;54:574579.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 33.

    Rooker GD, Wilkinson JD. Metal sensitivity in patients undergoing hip replacement: a prospective study. J Bone Joint Surg [Br] 1980;62-B:502505.

  • 34.

    Shanmugham HA, Handa S, De D, Dhillon MS, Aggarwal S. An observational study to determine the sensitizing potential of orthopedic implants. Indian J Dermatol Venereol Leprol 2020. doi: [Epub ahead of print].

    • Crossref
    • PubMed
    • Search Google Scholar
    • Export Citation
  • 35.

    Thomas P, Ständer S & Stauner Ket al. Arthroplasty patients and nickel sensitization: what do patch test and lymphocyte transformation test tell us. Semin Arthroplasty 2013;24:261264.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 36.

    Thomas B, Kulichova D, Wolf R, Summer B, Mahler V, Thomas P. High frequency of contact allergy to implant and bone cement components, in particular gentamicin, in cemented arthroplasty with complications: usefulness of late patch test reading. Contact Dermat 2015;73:343349.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 37.

    Thomas P, Braathen LR & Dörig Met al. Increased metal allergy in patients with failed metal-on-metal hip arthroplasty and peri-implant T-lymphocytic inflammation. Allergy 2009;64:11571165.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 38.

    Thyssen JP, Jakobsen SS, Engkilde K, Johansen JD, Søballe K, Menné T. The association between metal allergy, total hip arthroplasty, and revision. Acta Orthop 2009;80:646652.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 39.

    Waterman AH, Schrik JJ. Allergy in hip arthroplasty. Contact Dermat 1985;13:294301.

  • 40.

    Zeng Y, Feng W & Li Jet al. A prospective study concerning the relationship between metal allergy and post-operative pain following total hip and knee arthroplasty. Int Orthop 2014;38:22312236.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 41.

    Reed KB, Davis MD, Nakamura K, Hanson L, Richardson DM. Retrospective evaluation of patch testing before or after metal device implantation. Arch Dermatol 2008;144:9991007.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 42.

    Christiansen K, Holmes K, Zilko PJ. Metal sensitivity causing loosened joint prostheses. Ann Rheum Dis 1980;39:476480.

  • 43.

    Lhotka CG, Szekeres T & Fritzer-Szekeres Met al. Are allergic reactions to skin clips associated with delayed wound healing? Am J Surg 1998;176:320323.

  • 44.

    Davies AP, Willert HG, Campbell PA, Learmonth ID, Case CP. An unusual lymphocytic perivascular infiltration in tissues around contemporary metal-on-metal joint replacements. J Bone Joint Surg [Am] 2005;87-A:1827.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 45.

    Brien WW, Salvati EA & Betts Fet al. Metal levels in cemented total hip arthroplasty: a comparison of well-fixed and loose implants. Clin Orthop Relat Res 1992;276:6674.

    • PubMed
    • Search Google Scholar
    • Export Citation

 

  • Collapse
  • Expand
  • Fig. 1

    Preferred Reporting Items for Systematic Review and Meta-Analyses (PRISMA) study selection flow diagram.

  • 1.

    National Joint Registry (2020). 17th annual report 2020. https://reports.njrcentre.org.uk/Portals/0/PDFdownloads/NJR%2017th%20Annual%20Report%202020.pdf (date last accessed 3 March 2021).

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 2.

    Thyssen JP. Nickel and cobalt allergy before and after nickel regulation: evaluation of a public health intervention. Contact Dermat 2011;65:168.

  • 3.

    Amini M, Mayes WH, Tzeng A, Tzeng TH, Saleh KJ, Mihalko WM. Evaluation and management of metal hypersensitivity in total joint arthroplasty: a systematic review. J Long Term Eff Med Implants 2014;24:2536.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 4.

    Schäfer T, Böhler E & Ruhdorfer Set al. Epidemiology of contact allergy in adults. Allergy 2001;56:11921196.

  • 5.

    Akil S, Newman JM, Shah NV, Ahmed N, Deshmukh AJ, Maheshwari AV. Metal hypersensitivity in total hip and knee arthroplasty: current concepts. J Clin Orthop Trauma 2018;9:36.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 6.

    Baumann CA, Crist BD. Nickel allergy to orthopaedic implants: a review and case series. J Clin Orthop Trauma 2020;11:S596S603.

  • 7.

    Fregert S. Occupational dermatitis in a 10-year material. Contact Dermat 1975;1:96107.

  • 8.

    Shum KW, Meyer JD, Chen Y, Cherry N, Gawkrodger DJ. Occupational contact dermatitis to nickel: experience of the British dermatologists (EPIDERM) and occupational physicians (OPRA) surveillance schemes. Occup Environ Med 2003;60:954957.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 9.

    Kanerva L, Jolanki R, Estlander T, Alanko K, Savela A. Incidence rates of occupational allergic contact dermatitis caused by metals. Am J Contact Dermat 2000;11:155160.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 10.

    Yang K, Ren Y. Nickel-free austenitic stainless steels for medical applications. Sci Technol Adv Mater 2010;11:014105.

  • 11.

    Gao X, He RX, Yan SG, Wu LD. Dermatitis associated with chromium following total knee arthroplasty. J Arthroplasty 2011;26:665.e13665.e16.

  • 12.

    Delimar D, Bohaček I, Paštar Z, Lipozenčić J. Orthopedic and cutaneous reactions to nickel after total hip replacement. Acta Dermatovenerol Croat 2018;26:3943.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 13.

    OCEBM Levels of Evidence Working Group. The Oxford 2011 Levels of Evidence. Oxford Centre for Evidence-Based Medicine. http://www.cebm.net/index.aspx?o=5653 (date last accessed 3 March 2021).

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 14.

    Slim K, Nini E, Forestier D, Kwiatkowski F, Panis Y, Chipponi J. Methodological Index for Non-Randomized Studies (MINORS): development and validation of a new instrument. ANZ J Surg 2003;73:712716.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 15.

    Benson MK, Goodwin PG, Brostoff J. Metal sensitivity in patients with joint replacement arthroplasties. BMJ 1975;4:374375.

  • 16.

    Brown GC, Lockshin MD, Salvati EA, Bullough PG. Sensitivity to metal as a possible cause of sterile loosening after cobalt-chromium total hip-replacement arthroplasty. J Bone Joint Surg [Am] 1977;59-A:164168.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 17.

    Carlsson AS, Magnusson B, Möller H. Metal sensitivity in patients with metal-to-plastic total hip arthroplasties. Acta Orthop Scand 1980;51:5762.

  • 18.

    Carlsson A, Möller H. Implantation of orthopaedic devices in patients with metal allergy. Acta Derm Venereol 1989;69:6266.

  • 19.

    Christiansen RJ, Münch HJ & Bonefeld CMet al. Cytokine profile in patients with aseptic loosening of total hip replacements and its relation to metal release and metal allergy. J Clin Med 2019;8:1259.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 20.

    Deutman R, Mulder TJ, Brian R, Nater JP, Groningen M. Metal sensitivity before and after total hip arthroplasty. J Bone Joint Surg [Am] 1977;59-A:862865.

  • 21.

    Elves MW, Wilson JN, Scales JT, Kemp HB. Incidence of metal sensitivity in patients with total joint replacements. BMJ 1975;4:376378.

  • 22.

    Frigerio E, Pigatto PD, Guzzi G, Altomare G. Metal sensitivity in patients with orthopaedic implants: a prospective study. Contact Dermat 2011;64:273279.

  • 23.

    Granchi D, Cenni E, Trisolino G, Giunti A, Baldini N. Sensitivity to implant materials in patients undergoing total hip replacement. J Biomed Mater Res B Appl Biomater 2005;77:257264.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 24.

    Guenther D, Thomas P, Kendoff D, Omar M, Gehrke T, Haasper C. Allergic reactions in arthroplasty: myth or serious problem? Int Orthop 2016;40:239244.

  • 25.

    Gustafson K, Jakobsen SS & Lorenzen NDet al. Metal release and metal allergy after total hip replacement with resurfacing versus conventional hybrid prosthesis. Acta Orthop 2014;85:348354.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 26.

    Hallab NJ, Caicedo M, McAllister K, Skipor A, Amstutz H, Jacobs JJ. Asymptomatic prospective and retrospective cohorts with metal-on-metal hip arthroplasty indicate acquired lymphocyte reactivity varies with metal ion levels on a group basis. J Orthop Res 2013;31:173182.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 27.

    Hjorth MH, Stilling M & Søballe Ket al. No association between pseudotumors, high serum metal-ion levels and metal hypersensitivity in large-head metal-on-metal total hip arthroplasty at 5–7-year follow-up. Skeletal Radiol 2015;45:115125.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 28.

    Kręcisz B, Kieć-Świerczyńska M, Chomiczewska-Skóra D. Allergy to orthopedic metal implants: a prospective study. Int J Occup Med Environ Health 2012;25:463469.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 29.

    Lodi A, Chiarelli G, Mancini LL, Cancilleri F, Parrini L, Crosti C. Skin sensitivity to endoprosthetic materials in the recipients of hip prostheses. Contact Dermat 1995;32:5859.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 30.

    Milavec-Puretić V, Orlić D, Marusić A. Sensitivity to metals in 40 patients with failed hip endoprosthesis. Arch Orthop Trauma Surg 1998;117:383386.

  • 31.

    Nater JP, Brain RG, Deutman R, Mulder TJ. The development of metal hypersensitivity in patients with metal-to-plastic hip arthroplasties. Contact Dermat 1976;2:259261.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 32.

    Pazzaglia UE, Minoia C, Ceciliani L, Riccardi C. Metal determination in organic fluids of patients with stainless steel hip arthroplasty. Acta Orthop Scand 1983;54:574579.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 33.

    Rooker GD, Wilkinson JD. Metal sensitivity in patients undergoing hip replacement: a prospective study. J Bone Joint Surg [Br] 1980;62-B:502505.

  • 34.

    Shanmugham HA, Handa S, De D, Dhillon MS, Aggarwal S. An observational study to determine the sensitizing potential of orthopedic implants. Indian J Dermatol Venereol Leprol 2020. doi: [Epub ahead of print].

    • Crossref
    • PubMed
    • Search Google Scholar
    • Export Citation
  • 35.

    Thomas P, Ständer S & Stauner Ket al. Arthroplasty patients and nickel sensitization: what do patch test and lymphocyte transformation test tell us. Semin Arthroplasty 2013;24:261264.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 36.

    Thomas B, Kulichova D, Wolf R, Summer B, Mahler V, Thomas P. High frequency of contact allergy to implant and bone cement components, in particular gentamicin, in cemented arthroplasty with complications: usefulness of late patch test reading. Contact Dermat 2015;73:343349.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 37.

    Thomas P, Braathen LR & Dörig Met al. Increased metal allergy in patients with failed metal-on-metal hip arthroplasty and peri-implant T-lymphocytic inflammation. Allergy 2009;64:11571165.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 38.

    Thyssen JP, Jakobsen SS, Engkilde K, Johansen JD, Søballe K, Menné T. The association between metal allergy, total hip arthroplasty, and revision. Acta Orthop 2009;80:646652.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 39.

    Waterman AH, Schrik JJ. Allergy in hip arthroplasty. Contact Dermat 1985;13:294301.

  • 40.

    Zeng Y, Feng W & Li Jet al. A prospective study concerning the relationship between metal allergy and post-operative pain following total hip and knee arthroplasty. Int Orthop 2014;38:22312236.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 41.

    Reed KB, Davis MD, Nakamura K, Hanson L, Richardson DM. Retrospective evaluation of patch testing before or after metal device implantation. Arch Dermatol 2008;144:9991007.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 42.

    Christiansen K, Holmes K, Zilko PJ. Metal sensitivity causing loosened joint prostheses. Ann Rheum Dis 1980;39:476480.

  • 43.

    Lhotka CG, Szekeres T & Fritzer-Szekeres Met al. Are allergic reactions to skin clips associated with delayed wound healing? Am J Surg 1998;176:320323.

  • 44.

    Davies AP, Willert HG, Campbell PA, Learmonth ID, Case CP. An unusual lymphocytic perivascular infiltration in tissues around contemporary metal-on-metal joint replacements. J Bone Joint Surg [Am] 2005;87-A:1827.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 45.

    Brien WW, Salvati EA & Betts Fet al. Metal levels in cemented total hip arthroplasty: a comparison of well-fixed and loose implants. Clin Orthop Relat Res 1992;276:6674.

    • PubMed
    • Search Google Scholar
    • Export Citation